Cycling

FTP power zones calculator

Enter your FTP or a 20-minute test result to get the seven Coggan power zones in watts, the matching heart-rate ranges and your FTP in watts per kilo.

Metric and imperial Shareable link Printable report Free, no sign-up

Results

An FTP of 250 W at your weight is 3.33 W/kg, rated "Good" in the table Garmin publishes from Allen and Coggan’s work. Treat the label as a guide.
Functional threshold power250Wthe power you can hold for about an hour
Power to weight at FTP
3.33W/kg
Endurance (zone 2)
140–188 W
Tempo (zone 3)
190–225 W
Threshold (zone 4)
228–263 W
VO2 max (zone 5)
265–300 W
Upper limit of each zone

Your seven power zones

Zone% of FTPPowerHeart rateTypical use
1 · Active recovery< 55%under 138 Wunder 112 bpmEasy spinning
2 · Endurance56–75%140–188 W114–137 bpmLong steady rides
3 · Tempo76–90%190–225 W139–155 bpmBrisk, 1 to 3 hours
4 · Lactate threshold91–105%228–263 W157–173 bpmIntervals, 10–30 min
5 · VO2 max106–120%265–300 Wover 175 bpmIntervals, 3–8 min
6 · Anaerobic capacity121–150%303–375 W—Efforts, 30 s to 3 min
7 · Neuromuscular power—Maximal—Sprints under 30 s

Zones after Andrew Coggan. Coggan publishes zone 6 as "above 121%"; 150% is the working upper limit used in his book with Hunter Allen. Zone 7 is sprinting and has no power target.

FTP rating bands in watts at your weight

RatingW/kgPower at your weight
Superior5.05 and above379 W and above
Excellent3.93–5.04295–379 W
Good2.79–3.92209–295 W
Fair2.23–2.78167–209 W
Untrainedunder 2.23under 167 W

Garmin FTP ratings, credited to research by Hunter Allen and Andrew Coggan. Read on 2026-11-24.

  • Heart rate lags behind power by a minute or more and drifts upward with heat and fatigue. Use power for the target and heart rate as a check.

What FTP is

Functional threshold power is the highest power you can hold in a steady state for about an hour. Below it you can ride for a long time. Above it fatigue builds fast and the effort has a countdown. Andrew Coggan built his training levels around that one number, which is why every zone in the table is a percentage of it.

You do not have to ride flat out for an hour to find it. The common field test is 20 minutes all out, and FTP is taken as 95% of the average power. Pick 20-minute test average power in the calculator and it applies the 95% for you.

The zones

zone limit in watts = FTP × percentage ÷ 100
Level Name % of FTP % of threshold heart rate
1 Active recovery under 55% under 68%
2 Endurance 56–75% 69–83%
3 Tempo 76–90% 84–94%
4 Lactate threshold 91–105% 95–105%
5 VO2 max 106–120% over 106%
6 Anaerobic capacity 121% and above not applicable
7 Neuromuscular power not applicable not applicable

The percentages are the ones Coggan publishes. He gives level 6 as “above 121%”; the calculator shows 150% as its upper end, which is the working limit used in his book with Hunter Allen. Level 7 is a sprint of a few seconds and is ridden on feel.

Heart-rate ranges are percentages of your threshold heart rate, the average you hold in a long all-out effort, not of your maximum heart rate. Enter it if you know it. Leave it at zero and the table shows the percentages.

Worked example

The default is an FTP of 250 W for a 75 kg rider with a threshold heart rate of 165 bpm.

  • Zone 1: under 0.55 × 250 = under 138 W
  • Zone 2: 0.56 × 250 to 0.75 × 250 = 140–188 W
  • Zone 3: 0.76 × 250 to 0.90 × 250 = 190–225 W
  • Zone 4: 0.91 × 250 to 1.05 × 250 = 228–263 W
  • Zone 5: 1.06 × 250 to 1.20 × 250 = 265–300 W
  • Zone 6: 1.21 × 250 to 1.50 × 250 = 303–375 W
  • Power to weight: 250 ÷ 75 = 3.33 W/kg
  • Zone 2 heart rate: 0.69 × 165 to 0.83 × 165 = 114–137 bpm

Watt values are rounded to whole watts, which is why neighbouring zones leave a gap of a watt or two. No power meter is accurate to one watt, so the gap has no practical meaning.

Reading the result

The verdict line and the comparison bar rate your FTP per kilo against the bands Garmin prints in its Edge manuals, which Garmin credits to Allen and Coggan’s research:

Rating Men (W/kg) Women (W/kg)
Superior 5.05 and above 4.30 and above
Excellent 3.93–5.04 3.33–4.29
Good 2.79–3.92 2.36–3.32
Fair 2.23–2.78 1.90–2.35
Untrained under 2.23 under 1.90

The second table under the results converts those bands into watts at your body weight, so you can see how far the next band is. For the default rider, “excellent” starts at 295 W, which is 45 W away. The labels are a guide. They take no account of age, and a heavy rider with a modest W/kg can still be fast on flat roads.

Using the zones

  • Zone 2 is where most of the hours go. It should feel easy enough to talk in full sentences.
  • Zone 3 is steady work that builds fatigue quickly over long rides. Use it on purpose, not by drifting up from zone 2.
  • Zone 4 work is usually done as intervals of 10 to 30 minutes, with a total of 30 to 60 minutes in a session.
  • Zone 5 intervals last 3 to 8 minutes. If you cannot finish the set inside the range, the target is too high or your FTP is set too high.
  • Zones 6 and 7 are short efforts where average power matters less than repeating the effort well.

Average power for an interval should land inside the zone. Momentary spikes above it on a rise or out of a corner are normal.

Getting a reliable FTP

Test rested, on the same bike and power meter you train with, and on a stretch where you can pedal without interruption: a steady climb or an indoor trainer. Pace the 20 minutes so that the last five are the hardest. Starting too fast is the usual error, and it lowers the average. Indoor and outdoor numbers often differ by several percent, so set separate values if you train in both places.

Watts or watts per kilo

Zones are set in absolute watts because that is what your power meter shows and what your legs produce. Power per kilo only enters when you compare yourself with other riders or estimate climbing speed. If your weight changes and your FTP does not, your zones stay exactly where they were.

Limits

Zones are a convenience drawn on a continuum. Your body does not change gear at 75% or 90% of FTP, and day-to-day variation of a few percent is normal. The 95% rule also varies between riders: those with a large anaerobic capacity can hold well over 105% of their real threshold for 20 minutes, so their estimate runs high. If threshold intervals at the calculated power are never finishable, lower the FTP by 2 to 3% and try again.

Frequently asked questions

What are the 7 cycling power zones?
Coggan's levels are: 1 active recovery (under 55% of FTP), 2 endurance (56–75%), 3 tempo (76–90%), 4 lactate threshold (91–105%), 5 VO2 max (106–120%), 6 anaerobic capacity (121% and above) and 7 neuromuscular power, which is all-out sprinting with no power target.
How do I calculate FTP from a 20-minute test?
Multiply your average power for the 20 minutes by 0.95. A 20-minute average of 300 W gives an FTP of 285 W. The rule assumes you rode a hard 5-minute effort shortly before the 20 minutes, as the test protocol describes.
What is a good FTP?
Judge it per kilo. In the rating table Garmin publishes from Allen and Coggan's research, men are rated good from 2.79 W/kg and excellent from 3.93 W/kg; women are rated good from 2.36 W/kg and excellent from 3.33 W/kg. A 75 kg man with an FTP of 250 W sits at 3.33 W/kg, in the good band.
What power is zone 2 for an FTP of 250 W?
140 to 188 W. Zone 2 is 56 to 75% of FTP, so multiply your FTP by 0.56 and by 0.75.
Should I train by power zones or heart-rate zones?
Use power for the target when you have a power meter, because it responds instantly and does not drift. Heart rate lags by a minute or more and rises with heat, dehydration and fatigue at the same power. It is still a useful check on how hard a given power feels that day.
How often should I retest my FTP?
Every six to eight weeks during a training block is a common rhythm, and after any long break. If intervals at your zone 4 power start to feel clearly easier or impossible, the number is out of date.
Is sweet spot one of the Coggan zones?
No. Sweet spot is a coaching term for the overlap of upper tempo and lower threshold, usually given as about 88 to 94% of FTP. It is not one of the seven published levels, so the table does not list it.

Sources

  1. Coggan AR. Power Training Levels. TrainingPeaks
  2. Allen H, Coggan AR. Training and Racing with a Power Meter, 2nd ed. VeloPress, 2010
  3. Garmin Edge owner's manual: FTP Ratings (credited to Allen and Coggan)

Embed this calculator

Free for clubs, coaches, schools and blogs. Copy the code below; it stays up to date by itself.