What FTP is
Functional threshold power is the highest power you can hold in a steady state for about an hour. Below it you can ride for a long time. Above it fatigue builds fast and the effort has a countdown. Andrew Coggan built his training levels around that one number, which is why every zone in the table is a percentage of it.
You do not have to ride flat out for an hour to find it. The common field test is 20 minutes all out, and FTP is taken as 95% of the average power. Pick 20-minute test average power in the calculator and it applies the 95% for you.
The zones
| Level | Name | % of FTP | % of threshold heart rate |
|---|---|---|---|
| 1 | Active recovery | under 55% | under 68% |
| 2 | Endurance | 56–75% | 69–83% |
| 3 | Tempo | 76–90% | 84–94% |
| 4 | Lactate threshold | 91–105% | 95–105% |
| 5 | VO2 max | 106–120% | over 106% |
| 6 | Anaerobic capacity | 121% and above | not applicable |
| 7 | Neuromuscular power | not applicable | not applicable |
The percentages are the ones Coggan publishes. He gives level 6 as “above 121%”; the calculator shows 150% as its upper end, which is the working limit used in his book with Hunter Allen. Level 7 is a sprint of a few seconds and is ridden on feel.
Heart-rate ranges are percentages of your threshold heart rate, the average you hold in a long all-out effort, not of your maximum heart rate. Enter it if you know it. Leave it at zero and the table shows the percentages.
Worked example
The default is an FTP of 250 W for a 75 kg rider with a threshold heart rate of 165 bpm.
- Zone 1: under 0.55 × 250 = under 138 W
- Zone 2: 0.56 × 250 to 0.75 × 250 = 140–188 W
- Zone 3: 0.76 × 250 to 0.90 × 250 = 190–225 W
- Zone 4: 0.91 × 250 to 1.05 × 250 = 228–263 W
- Zone 5: 1.06 × 250 to 1.20 × 250 = 265–300 W
- Zone 6: 1.21 × 250 to 1.50 × 250 = 303–375 W
- Power to weight: 250 ÷ 75 = 3.33 W/kg
- Zone 2 heart rate: 0.69 × 165 to 0.83 × 165 = 114–137 bpm
Watt values are rounded to whole watts, which is why neighbouring zones leave a gap of a watt or two. No power meter is accurate to one watt, so the gap has no practical meaning.
Reading the result
The verdict line and the comparison bar rate your FTP per kilo against the bands Garmin prints in its Edge manuals, which Garmin credits to Allen and Coggan’s research:
| Rating | Men (W/kg) | Women (W/kg) |
|---|---|---|
| Superior | 5.05 and above | 4.30 and above |
| Excellent | 3.93–5.04 | 3.33–4.29 |
| Good | 2.79–3.92 | 2.36–3.32 |
| Fair | 2.23–2.78 | 1.90–2.35 |
| Untrained | under 2.23 | under 1.90 |
The second table under the results converts those bands into watts at your body weight, so you can see how far the next band is. For the default rider, “excellent” starts at 295 W, which is 45 W away. The labels are a guide. They take no account of age, and a heavy rider with a modest W/kg can still be fast on flat roads.
Using the zones
- Zone 2 is where most of the hours go. It should feel easy enough to talk in full sentences.
- Zone 3 is steady work that builds fatigue quickly over long rides. Use it on purpose, not by drifting up from zone 2.
- Zone 4 work is usually done as intervals of 10 to 30 minutes, with a total of 30 to 60 minutes in a session.
- Zone 5 intervals last 3 to 8 minutes. If you cannot finish the set inside the range, the target is too high or your FTP is set too high.
- Zones 6 and 7 are short efforts where average power matters less than repeating the effort well.
Average power for an interval should land inside the zone. Momentary spikes above it on a rise or out of a corner are normal.
Getting a reliable FTP
Test rested, on the same bike and power meter you train with, and on a stretch where you can pedal without interruption: a steady climb or an indoor trainer. Pace the 20 minutes so that the last five are the hardest. Starting too fast is the usual error, and it lowers the average. Indoor and outdoor numbers often differ by several percent, so set separate values if you train in both places.
Watts or watts per kilo
Zones are set in absolute watts because that is what your power meter shows and what your legs produce. Power per kilo only enters when you compare yourself with other riders or estimate climbing speed. If your weight changes and your FTP does not, your zones stay exactly where they were.
Limits
Zones are a convenience drawn on a continuum. Your body does not change gear at 75% or 90% of FTP, and day-to-day variation of a few percent is normal. The 95% rule also varies between riders: those with a large anaerobic capacity can hold well over 105% of their real threshold for 20 minutes, so their estimate runs high. If threshold intervals at the calculated power are never finishable, lower the FTP by 2 to 3% and try again.
Frequently asked questions
What are the 7 cycling power zones?
How do I calculate FTP from a 20-minute test?
What is a good FTP?
What power is zone 2 for an FTP of 250 W?
Should I train by power zones or heart-rate zones?
How often should I retest my FTP?
Is sweet spot one of the Coggan zones?
Sources
- Coggan AR. Power Training Levels. TrainingPeaks
- Allen H, Coggan AR. Training and Racing with a Power Meter, 2nd ed. VeloPress, 2010
- Garmin Edge owner's manual: FTP Ratings (credited to Allen and Coggan)
Embed this calculator
Free for clubs, coaches, schools and blogs. Copy the code below; it stays up to date by itself.