What you are watching
A 2,000 m course from above with buoy lines, 500 m markers and four boats. The boats are a picture only: every time on this page was rowed on an indoor rowing machine, where the display counts metres the same way for everyone.
| Lane | Rower | 2,000 m | Average split | Average power |
|---|---|---|---|---|
| 1 | Oliver Zeidler (GER), 2026 | 5:34.7 | 1:23.7 | 597 W |
| 2 | Josh Dunkley-Smith (AUS), 2018 | 5:35.8 | 1:24.0 | 592 W |
| 3 | Brooke Mooney (USA), 2021 | 6:21.1 | 1:35.3 | 405 W |
| 4 | You | your time |
Lane 1 is the current men’s record. Lane 2 is the mark it replaced after eight years, and the two boats stay within seven metres of each other for the whole race. Lane 3 is the fastest 2,000 m recorded by a woman.
The strip at the top works like the monitor on the machine: it shows your current 500 m split and watts, next to your gap to the record in metres. An eight-minute piece plays in about 36 seconds at 1×. Drag the bar under the course, or use the arrow keys, to move through the race.
Worked example
The default is 8:00.0 with even splits.
- Split: 480 s ÷ 4 = 2:00.0 per 500 m
- Pace per metre: 120 ÷ 500 = 0.24 s. Power: 2.80 ÷ 0.24³ = 203 W
- The record ends at 5:34.7, which is 334.7 s. You have rowed 2,000 × 334.7 ÷ 480 = 1,395 m
- Still to row: 605 m
- The record holder waits 8:00.0 − 5:34.7 = 2:25.3
The other lanes work the same way. The 5:35.8 ends with you at 1,399 m. The 6:21.1 ends with you at 1,588 m, 412 m from the line, and its rower waits 1:38.9.
Now load the 7:00 preset. A 7:00 rower is at 1,594 m when the record ends, 406 m short, and the wait drops to 1:25.3. One minute off your time has moved you 199 m up the course. The presets (9:00, 8:00, 7:00 and 6:20) are round examples and not averages of any group of rowers.
Compare the speeds and the powers. You are moving at 334.7 ÷ 480 = 69.7% of record speed. Your power is 203 ÷ 597 = 33.9% of record power. Getting from one to the other is a matter of tripling the watts.
Split and watts
The Concept2 monitor calculates power from pace with one formula.
The cube is the important part. It reflects how the drag of the flywheel, like the drag of water on a hull, grows with speed.
| 2,000 m time | Split per 500 m | Watts | Position when the record ends |
|---|---|---|---|
| 9:00 | 2:15.0 | 142 | 1,240 m |
| 8:00 | 2:00.0 | 203 | 1,395 m |
| 7:00 | 1:45.0 | 302 | 1,594 m |
| 6:20 | 1:35.0 | 408 | 1,762 m |
| 5:34.7 | 1:23.7 | 597 | 2,000 m |
Two minutes off a 9:00, down to 7:00, more than doubles the power. The last 45 seconds from 6:20 to the record need almost half as much again.
The race profile
Nobody rows four identical 500 m sections in a race. Garland analysed elite 2,000 m races and found the same shape on the water and on the machine: a fast first 500 m, a slower middle and a lift at the end. For ergometer racing the four sections averaged 101.5%, 99.8%, 99.0% and 99.7% of the rower’s mean speed. On the water the start was faster still, at 103.3%.
The three reference lanes use the ergometer profile, scaled to each final time. For the record that gives sections of 1:22.4, 1:23.8, 1:24.5 and 1:23.9. Your lane rows even splits unless you choose Race profile, which applies the same four percentages to your time.
The difference between the two shapes is small in metres. With the race profile an 8:00 rower passes 500 m in 1:58.2, 1.8 s earlier than on even splits, and that is about seven metres.
What is assumed
- Measured: the three finishing times.
- Modelled: the splits inside each reference piece. They follow the average elite profile and are not the splits those rowers produced on the day.
- Averaged: watts shown for a section come from that section’s split. Real power varies stroke by stroke.
- Not modelled: the first few strokes from a standing flywheel, drag factor settings, and fatigue. The stage does not animate individual strokes.
- Status of the women’s mark: the 6:21.1 was reported by World Rowing in 2021 and was still listed as the record in its January 2025 review. No faster piece was found when this page was checked on 24 November 2026.
Weight classes and age groups have their own records. This page uses the fastest pieces overall.
Reading the results
Still to row when the record piece ends is your distance from the line when lane 1 finishes. The first table gives the same number for each reference rower with their split and watts. The second table is your race in four sections, with the watts each section needs and the gap to the record at the end of it.
Try your current time, then the time you are training for, and look at the power column. That difference in watts is what the training has to produce.
Frequently asked questions
What is the 2,000 m rowing machine world record?
What is a good 2k erg time?
How do I convert a 500 m split to watts?
How far behind the world record would an 8-minute 2k finish?
Why does a small gain in speed take so many more watts?
Should I row even splits in a 2k test?
Is a 2k on the rowing machine the same as 2,000 m on the water?
Sources
- Concept2: Indoor rowing world records fall in 2026 (2,000 m in 5:34.7)
- World Rowing: World's fastest for indoor rowing 2k, who is Brooke Mooney? (6:21.1), 1 April 2021
- World Rowing: Trends in indoor rowing records, 23 January 2025
- Garland SW. An analysis of the pacing strategy adopted by elite competitors in 2000 m rowing. British Journal of Sports Medicine 39(1), 2005, pp. 39–42
- Concept2: pace and watts calculator (watts = 2.80 ÷ pace³)